1. India
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Outdoor Termination Kits 5670 Series

3M™ Cold Shrink QT-II Outdoor Termination Kits 5670 Series

  • Options available
  • | Select product options for IDs.

One-piece cold shrink termination

High dielectric-constant material regulates the distribution of electric field stress

Suitable for indoor applications

View more details
Frequently viewed resources
PDF (1) Copy 26Tech Data Sheet (PDF, 230KB)
icn_down_arrow

Select product options

Details

Highlights
  • One-piece cold shrink termination
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for indoor applications
  • Non-tracking, silicone rubber insulation offers durability
  • Withstands voltages up to 15kV and is 110 kV BIL-rated
  • Includes a non-skirted, 1-piece termination
  • Meets IEEE Standard 48 Class 3 for indoor, weather-protected applications

3M™ Cold Shrink QT-II Silicone Rubber Termination Kits QT-II 5670 Series will terminate CN or JCN cables and can be used for both indoor (protected) and outdoor (weather-exposed) applications.

Each 3M™ Cold Shrink QT-II Silicone Rubber Termination Kit QT-II 5670 Series includes one each of: Hi-K silicone rubber termination, Silicone rubber terminator, Packet of silicone grease and Instruction sheet

Typical Properties

Applications

Cable Termination

BIL

110 kV

Brands

3M™

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

16.2-28.4 mm, 23.8-46.0 mm

Cable Type

Polymeric insulated, copper wire screened, unarmored cable

Case Quantity

10

Indoor/Outdoor

Indoor Non-skirted

Insulation Level

100%, 133%

Insulation O.D. Range (Metric)

16.2-28.4 mm

Insulation Outer Diameter (metric)

16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm, 45.974 mm

Insulation Rejacketing

No

Lug/Stem Connector Included in Kit

No

Material

Silicone Rubber

Number of Conductors

1

Product Colour

Grey

Product Series

5670

Shielding Type

Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

Voltage

15 kV

Voltage Rating

6/10 kV