1. India
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-II Outdoor Termination Kits 5690K Series

3M™ Cold Shrink QT-II Outdoor Termination Kits 5690K Series

  • Options available
  • | Select product options for IDs.

One-piece cold shrink termination

High dielectric-constant material regulates the distribution of electric field stress

Suitable for outdoor, weather exposed applications

View more details
Frequently viewed resources
PDF (1) Copy 26Tech Data Sheet (PDF, 2MB)
icn_down_arrow
icn_down_arrow
icn_down_arrow

Select product options

Details

Highlights
  • One-piece cold shrink termination
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor, weather exposed applications
  • Silicone rubber insulation is track-resistance and hydrophobic
  • Silicone cold shrink application provides constant radial pressure, "living seal"
  • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications

The 3M™ Cold Shrink QT-II Outdoor Termination Kit includes three 6 skirt, 1 piece terminations. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables.

The 3M™ Cold Shrink QT-II Outdoor Termination Kit offers a conjunction of high dielectric constant material and silicone rubber insulation which allows the termination to withstand voltages of 15 to 25/28 kV.

Typical Properties

Applications

Cable Termination

BIL

150 kV, 200 kV

Breakout Boot

No

Cable Insulation Outside Diameter Range (metric)

27.9-41.9 mm, 33.0-49.5 mm, 21.3-33.8 mm, 16.3-22.9 mm

Case Quantity

1

Indoor/Outdoor

Outdoor Skirted

Insulation Level

100%, 133%

Insulation Outer Diameter (metric)

16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm, 45.974 mm, 46.228 mm, 46.482 mm, 46.736 mm, 46.99 mm, 47.244 mm, 47.498 mm, 47.752 mm, 48.006 mm, 48.26 mm, 48.514 mm, 48.768 mm, 49.022 mm, 49.276 mm, 49.53 mm

Insulation Rejacketing

No

Jacket Outside Diameter Range (metric)

20,3-30,5 mm, 25,4-40,6 mm, 33,0-48,3 mm, 38,1-61,0 mm, 25.4-40.6 mm, 33.0-48.2 mm, 38.1-61.0 mm

Lug/Stem Connector Included in Kit

No

Maximum Installed Length (metric)

381 mm (Tape and Wire Shield) 368 mm (UniShield®), 419 mm (Tape and Wire Shield) 406 mm (UniShield®), 425 mm (Tape and Wire Shield) 413 mm (UniShield®), 495 mm (Tape and Wire Shield) 483 mm (UniShield®), 546 mm (Tape and Wire Shield) 533 mm (UniShield®), 552 mm (Tape and Wire Shield) 540 mm (UniShield®)

Number of Conductors

1

Number of Skirts

6 , 8

Product Series

5690K, 7600-T-3G

Shielding Type

UniShield®, Wire Shield, Tape Shield, Wire-Over-Tape Shield

Voltage

15 kV, 25 kV, 35 kV

Resources