1-piece inline splice is perfect to repair damaged JCN or CN cables up to 6 inches

Excellent electrical stress distribution

Molded from specially formulated, peroxide-cured EPDM rubbers

View more details
icn_down_arrow

Select product options

Details

Highlights
  • 1-piece inline splice is perfect to repair damaged JCN or CN cables up to 6 inches
  • Excellent electrical stress distribution
  • Molded from specially formulated, peroxide-cured EPDM rubbers
  • Rated for 15 kV cables
  • Factory-tested to offer reliability
  • Meets the requirements of IEEE 404 standards

3M™ 5411R Series Molded Rubber QS II Splice Kit is a 15kV 1 piece inline splice perfect to repair damaged cables. It is suitable to use on 15kV jacketed concentric neutral (JCN) or concentric neutral (CN) cables with copper or aluminium conductors. Its elongated design ensures the easy removal of damaged cables up to 6 inches.

3M™ 5411R Series QS II Splice Kit includes an EPDM molded rubber splice body, a packet of silicone grease and an instruction sheet. It replaces up to 6 inches of damaged cable, thereby eliminating the need to splice in a new section of cable with 2 separate splices. It is suitable to use on cables that can withstand a maximum temperature of 90 °C. The splice is molded from specially formulated, peroxide cured EPDM rubbers to provide physical protection. Connectors bridge the gap where the damaged cable is removed. The kit meets the requirements of IEEE 404 standards.

Typical Properties

Case Quantity

1

Connector Included

CIR-2, CIR-1/0, CIR-2/0, CIR-21, CIR-22, CIR-3/0, CIR-4/0, CIR-1/0 and two 10002, None

Insulation Outer Diameter (metric)

16 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm

Insulation Outside Diameter Range (metric)

16.3 - 22.9 mm, 22.1 - 26.9 mm

Number of Conductors

1

Operating Voltage

15 kV

Product Series

5411R & 5412R Series

Product Type

Inline Repair

Shielding Type

Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

Splice Type

Inline Repair

Voltage

25/28 kV