3M™ Cold Shrink QT III 7640 S INV & 7650 S INV Series Inverted Termination Kit includes a single conductor, skirted termination. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.
BIL | 110 kV, 200 kV |
Brands | 3M™ |
Breakout Boot | No |
Cable Insulation Outside Diameter Range (metric) | 17,5-31,0 mm, 18.3-32.8 mm, 26.7 - 45.7 mm, 38.9 - 58.9 mm, 16.3 - 27.4 mm |
Case Quantity | 1 |
Compatible Lug | QL2-A-2-250, QL2-A-4/0-600, QL2-A-350-750, QL2-A-500-1000, QL2-A-1000-1250 |
Indoor/Outdoor | Outdoor, Indoor Non-skirted, Outdoor Skirted Inverted |
Insulation Level | 100%, 133% |
Insulation Outer Diameter (metric) | 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm, 45.974 mm, 46.228 mm, 46.482 mm, 46.736 mm, 46.99 mm, 47.244 mm, 47.498 mm, 47.752 mm, 48.006 mm, 48.26 mm, 48.514 mm, 48.768 mm, 49.022 mm, 49.276 mm, 49.53 mm, 49.784 mm, 50.038 mm, 50.292 mm, 50.546 mm, 50.8 mm, 51.054 mm, 51.308 mm, 51.562 mm, 51.816 mm, 52.07 mm, 52.324 mm, 52.578 mm, 52.832 mm, 53.086 mm, 53.34 mm, 53.594 mm, 53.848 mm, 54.102 mm, 54.356 mm, 54.61 mm, 54.864 mm, 55.118 mm, 55.372 mm, 55.626 mm, 55.88 mm, 56.134 mm, 56.388 mm, 56.642 mm, 56.896 mm, 57.15 mm, 57.404 mm, 57.658 mm, 57.912 mm, 58.166 mm, 58.42 mm, 58.674 mm, 58.928 mm |
Insulation Rejacketing | No |
Number of Conductors | 1 |
Number of Skirts | 2 , 4 |
Product Series | 7640-S-INV, 7650-S-INV |
Shielding Type | Concentric Neutral (CN), Jacketed Concentric Neutral (JCN) |
Voltage | 5 kV, 8 kV, 15 kV, 25 kV, 35 kV, 25/28 kV |
Voltage Application | Medium Voltage |